Page view 12
Sand Blasting
Hook Up Guide
MicroEtcher & MicroProphy Quick Disconnects
Chairside
The barbed tee is
installed directly in
the incoming air line,
either in the cart or
in the junction box.
Cut the air line to
install the tee.
Quick Disconnect Kit
Male & female with barbed
tee for 1/4” air line.*
PN 44000
Initial Hook Up Kit
Chairside
As above.
Female Only
Quick disconnect with barb
tee for 1/4” air line.*
PN 44010
Secondary Outlet Kits
Laboratory Stopcock
Slip tubing end over
the stopcock.
Female Only
Quick disconnect.
PN 44017
Handpiece Line
Screw on the
adapter. Adjust the
air pressure.
4-5 Hole Handpiece
Adapter
PN 44075
Male Only Quick Disconnect
PN 44020
Quick Disconnect Installa tion: The
MicroEtcher and Microprophy are
designed to operate over a pressure
range of 50 to 120 psi (3.4 - 8.3 bars).
Either can be installed using one of
three options: a Quick Disconnect
Kit, a Laboratory Quick Disconnect
or a Handpiece Adapter. A review of
the following information will help you
decide which adapter is best suited to
your needs. Higher pressures will lead to
superior performance.
Option 1
Quick Disconnect Kit: The Quick
Disconnect Kit is designed to be used in
the operatory for chairside sandblasting.
The kit consists of a female disconnect, a
tee which is spliced into the line coming
from the compressor before the pressure
regulator (i.e., junction box or cart),
and a separate male connection. The
male connection is installed on the end
of the MicroEtcher tubing. A tee (with
the female connection) may be installed
in more than one operatory so that the
MicroEtcher with its male disconnect may
be used in each room.
Option 2
Lab Quick Disconnect Kit: In the
laboratory there is generally an air line
with 80 - 100 psi (5.5 - 6.9 bars) pressure.
If an air jet (stopcock) is present, the
Lab Quick Disconnect with its female
disconnect is designed to be permanently
installed on it. The male disconnect is
installed on the end of the MicroEtcher
tubing. With a female Quick Disconnect
installed in the lab, and also in the
operatory, the MicroEtcher can be used in
both places.
Option 3
Handpiece Adapter: If there is an extra
handpiece line in the operatory which can
be adjusted to 50 psi or more (3.4 bars),
the handpiece adapter can be installed on
the end of the MicroEtcher tubing.
* Special hook up connections, i.e., tees, plastic and copper lines are also available.
Contact our Customer Service Department for assistance.
Female
Barbed Tee
Male
Female
Screw on Outlet
Slip Over Stopcock
S
Scr
ew
Female
Sl
i
p O
ver
S
t
opc
ock
y
Description
Diagram
Air Source
50 - 120 Psi
(3.5 - 8 Bars)
Female
Barbed Tee
Barbed Te
e
Handpiece Adapter
Kavo Style
Kavo Adapter
PN 201431-00
Screw on Outlet
Scr
ew
Laboratory Stopcock
Slip tubing end over
the stopcock.
Female & Male
Quick disconnect.
PN 44007
Female Slip Over Stopcock
Fe
m
ale
Sl
i
p
O
ver
S
t
o
Male
13
Call 800/827-7940 or visit danvillematerials.com
Page view 12