ELECTRICAL SYSTEM 16-15
Battery
Refreshing Charge
Remove the battery [A] (see B attery Removal).
Do refresh-charge by following method according to the
battery terminal voltage.
WARNING
This battery is sealed type. Never remove seal cap
[B] even at charging. Never add water. Charge with
current and time as stated below.
Terminal Vo ltage: 11.5 less than 12.6 V
Standard Charge
1.8 A × 5 10 h (see following
chart)
Quick Charge
9.0 A × 1.0 h
CAUTION
If possible, do not quick charge. If the quick charge
is done due to unavoidable circumstances, do stan-
dard charge later on.
Terminal Voltage: less than 11.5 V
Charging Method:
1.8A×20h
NOTE
Increase the charging voltage to a maximum voltage of
25 V if the battery will not accept current initially. Charge
for no more than five minutes at the increased voltage
then check if the battery is drawing current.
If the battery will accept current, decrease the voltage
and charge by the standard charging method described
on the battery case.
If the battery will not accept current after 5 minutes, re-
place the battery.
Battery [A]
Battery Charger [B]
Standard Value [C]