16-46 ELECTRICAL SYSTEM
Fuses
Fuse Removal
Unlock the hook to lift up the lid [A].
Pull the fuses [B] straight out of the fuse box with a needle
nose pliers.
Fuse Installation
If a fuse fails during operation, inspect the electrical sys-
tem to determine the cause, and then replace it with a
new fuse of proper amperage.
Install the fuse box fuses on the original position as spec-
ified on the lid.
Fuse Inspection
Remove the fuse.
Inspect the fuse element.
If it is blown out, replace the fuse. Before replacing a
blown fuse, always check the amperage in the affected
circuit. If the amperage is equal to or greater than the
fuse rating, check the wiring and related components for
a short circuit.
Housing [A]
Fuse Element [B]
Terminals [C]
Blown Element [D]
CAUTION
When replacing a fuse, be sure the new fuse
matches the specified fuse rating for that circuit.
Installation of a fuse with a higher rating may cause
damage to wiring and components.