4-4 COOLING SYSTEM
Specifications
Item Standard
Coolant
Type (Recommended) Permanent type of antifreeze (soft water and ethylene glycol
plus corrosion and rust inhibitor chemicals for aluminum
engines and radiators)
Color Green
Mixed Ratio Soft water 50%, coolant 50%
Freezing Point
–35°C (–31°F)
Total Amount
4.1 L (4.3 US qt)
Radiator Cap
Relief Pressure 93 ∼ 123 kPa (0.95 ∼ 1.25 kgf/cm², 13 ∼ 18 psi)
Thermostat
Valve Opening Temperature 81 ∼ 84°C (178 ∼ 183°F)
Valve Full Opening Temperature 95°C (203°F)