PERIODIC MAINTENANCE 2-41
Periodic Maintenance Procedures
Frame
Seat Belt Inspection
Check the belts [A] for damage or tear.
If necessary, replace the belt w ith a new one.
Check the tightness torque of the following bolts.
Torque - Seat Belt Mounting Bolts [B]: 34 N·m (3.5 kgf·m,
25 ft·lb)
Seat Belt Buckle Mounting Bolts [C]: 34 N·m (3.5
kgf·m, 25 ft·lb)
Check the operation of the buckle [A].
Set the plate [B] in the buckle, and confirm the plate does
not come off when pulling it.
Set the plate in the buckle, and confirm the plate comes
off when the buckle button [C] is pushed.
If operation is not correct, visually inspect the plate.
If the plate is damaged, replace the plate assembly with
a new one.
If the plate is not damaged, replace the buckle assembly.
Electrical System
Electrolyte Level Inspection (Conventional Type
Battery)
WARNING
Electrolyte contains sulfuric acid which is harmful
to skin, eyes, and clothing.
Wear eye protection and rubber gloves.
If spillage occurs on body or clothing, rinse at once
with water for at least 15 minutes.
Remove the filler caps [A] on the battery.
Lift the side of the cap [B] opposite the terminals, and then
lift the side of the cap nearest the terminals.