COOLING SYSTEM 4-13
Hoses and Pipes
Hose and Pipe Installation
•
Install the hoses and pipes being careful to follow bend-
ing direction or diameter. Avoid sharp bending, kinking,
flattening, or twisting.
•
Install the clamps [A] as near as possible to the hose end
to clear the raised rib or the fitting. This will prevent the
hoses from working loose.
○
The clamp screws should be positioned correctly to pre-
vent the clamps from contacting anything.
•
Install the water pipes [A].
•
Tighten:
Torque - Water Pipe Mounting Bolts [B]: 8.8 N·m (0.90
kgf·m, 78 in·lb)
Hose Inspection
•
Refer to the Radiator Hose and Connection Inspection in
the Periodic Maintenance chapter.